MGate 5119 Series
1-port DNP3/IEC 101/IEC 104/Modbus-to-IEC 61850 gateways
Features and Benefits
Supports IEC 61850 MMS server
Supports DNP3 serial/TCP master
Supports IEC 60870-5-101 master (balanced/unbalanced)
Supports IEC 60870-5-104 client
Supports Modbus RTU/ASCII/TCP master/client
Embedded traffic monitoring/diagnostic information for easy troubleshooting and cloud data transmission for cost evaluation and analysis
Built-in Ethernet cascading for easy wiring
-40 to 75°C operating temperature range
Serial port with 2 kV isolation protection
Supports IEC 61850 MMS and DNP3 TCP protocol encryption
Compliant with IEC 61850-3 and IEEE 1613
Built-in SCL file generator for easy configuration
-
MGate 5121 Series
1-port CAN-to-Modbus TCP gateways
Features and Benefits
Simultaneous protocol conversions from CANopen, J1939, and proprietary CAN (CAN 2.0A/B) to Modbus TCP and SNMP
Supports Modbus TCP Server (Slave) and SNMP Agent
Supports CANopen master, J1939, and proprietary CAN (CAN 2.0A/B)
Flexible deployment with Ethernet cascading and dual subnet
Embedded traffic monitoring/diagnostic information for easy troubleshooting
Easy device configuration via a web-based console
microSD card for configuration backup/duplication
Supports dual redundant DC power inputs and 1 relay output
CAN port with 2-kV isolation protection
Compliance with IEC 62443-4-2 Security Level 2 requirements
-40 to 75°C wide operating temperature models available
-
MGate 5134 Series
1-port Modbus RTU/ASCII/TCP-to-PROFINET gateways
Features and Benefits
Protocol conversion from Modbus to PROFINET
Supports PROFINET IO device
Supports Modbus RTU/ASCII/TCP Client (Master)
Flexible deployment with Ethernet cascading and dual subnet
Embedded traffic monitoring/diagnostic information for easy troubleshooting
Easy device configuration via a web-based console
microSD card for configuration backup/duplication
Supports dual redundant DC power inputs and 1 relay output
Serial port with 2 kV isolation protection
-40 to 75°C wide operating temperature models available
-
MGate 5135/5435 Series
1 and 4-port Modbus RTU/ASCII/TCP-to-EtherNet/IP gateways
Features and Benefits
Protocol conversion between Modbus and EtherNet/IP
Supports EtherNet/IP adapter
Supports Modbus RTU/ASCII/TCP Client (Master)
Flexible deployment with Ethernet cascading and dual subnet
Embedded traffic monitoring/diagnostic information for easy troubleshooting
Easy device configuration via a web-based console
microSD card for configuration backup/duplication
Supports dual redundant DC power inputs and 1 relay output
-40 to 75°C wide operating temperature models available
Serial port with 2 kV isolation protection
-
MGate 5192 Series
1-port IEC 61850-to-DNP3/IEC 101/IEC 104/Modbus gateways
Supports IEC 61850 MMS client
Supports DNP3 serial/TCP/UDP outstation
Supports IEC 60870-5-101 server
Supports IEC 60870-5-104 client
Supports Modbus RTU/ASCII/TCP Server (Slave)
Flexible deployment with Ethernet cascading and dual subnet
Embedded traffic monitoring/diagnostic information for easy troubleshooting
Easy device configuration via a web-based console
microSD card for configuration backup/duplication
Supports dual redundant DC power inputs and 1 relay output
Serial port with 2 kV isolation protection
Compliance with IEC 62443-4-2 Security Level 2 requirements
-40 to 75°C wide operating temperature models available
-
MGate 5216 Series
2-port serial/Modbus-to-EtherCAT gateways
Features and Benefits
Protocol conversion from proprietary serial or Modbus to EtherCAT
Supports EtherCAT slave
Supports Modbus RTU/ASCII Client (Master)
Maximum data input and output of 512 bytes
Serial port with 2 kV isolation protection
Supports MicroPython programming for proprietary serial
Built-in Ethernet cascading for easy wiring
Supports redundant dual DC power inputs and 1 relay output
-
MGate 5217 Series
2-port Modbus RTU/ASCII/TCP-to-BACnet/IP gateways
Features and Benefits
Supports Modbus RTU/ASCII/TCP Client (Master) / Server (Slave)
Supports BACnet/IP Server / Client
Supports 600 points and 1200 points models
Supports COV for fast data communication
Supports virtual nodes designed to make each Modbus device as a separate BACnet/IP device
Supports quick configuration of Modbus commands and BACnet/IP objects by editing an Excel spreadsheet
Embedded traffic and diagnostic information for easy troubleshooting
Built-in Ethernet cascading for easy wiring
Industrial design with -40 to 75°C operating temperature range
Serial port with 2 kV isolation protection
Dual AC/DC power supply
5-year warranty
-
MGate MB3170-G2/MB3270-G2/MB3470-G2 Series
1, 2, and 4-port advanced serial-to-Ethernet Modbus gateways compliant with IEC62443-4-2
Features and Benefits
Supports high-performing and low-latency agent mode to actively poll Modbus devices and cache data
Supports proprietary Modbus and Modbus extensions for various devices
Supports Auto Device Routing for easy configuration
Supports route by TCP port or IP address for different system architectures
Connects up to 32 Modbus TCP clients (MGate can queue 32 Modbus requests for each Modbus client connected)
Supports Modbus serial client to Modbus serial server communications
Ethernet cascading or dual subnet for flexible network system design
10/100BaseTX (RJ45) or 100BaseFX (single mode or multi-mode with SC/ST connector or SFP option)
Modbus communication test tools independant of external software
Intuitive Modbus diagnostics and traffic monitoring for easy troubleshooting
Serial port with 2 kV isolation protection (for -I models)
Supports redundant dual DC power inputs and 1 relay output
Compliance with IEC 62443-4-2 Security Level 2 requirements
-40 to 75°C wide operating temperature range (-T models)
-
MGate MB3180/MB3280/MB3480 Series
1, 2, and 4-port standard serial-to-Ethernet Modbus gateways
Features and Benefits
Supports Auto Device Routing for easy configuration
Supports route by TCP port or IP address for flexible deployment
Converts between Modbus TCP and Modbus RTU/ASCII protocols
1 Ethernet port and 1, 2, or 4 RS-232/422/485 ports
16 simultaneous TCP masters with up to 32 simultaneous requests per master
Easy hardware setup and configuration
-
MGate MB3170/MB3270 Series
1 and 2-port advanced serial-to-Ethernet Modbus gateways
Features and Benefits
Supports Auto Device Routing for easy configuration
Supports route by TCP port or IP address for flexible deployment
Connects up to 32 Modbus TCP servers
Connects up to 31 or 62 Modbus RTU/ASCII slaves
Accessed by up to 32 Modbus TCP clients (retains 32 Modbus requests for each Master)
Supports Modbus serial master to Modbus serial slave communications
Built-in Ethernet cascading for easy wiring
10/100BaseTX (RJ45) or 100BaseFX (single mode or multi-mode with SC/ST connector)
Emergency request tunnels ensure QoS control
Embedded Modbus traffic monitoring for easy troubleshooting
Serial port with 2 kV isolation protection (for “-I” models)
-40 to 75°C wide operating temperature models available
Supports redundant dual DC power inputs and 1 relay output
-
MGate MB3660 Series
8 and 16-port redundant Modbus gateways
Features and Benefits
Supports Auto Device Routing for easy configuration
Supports route by TCP port or IP address for flexible deployment
Innovative Command Learning for improving system performance
Supports agent mode for high performance through active and parallel polling of serial devices
Supports Modbus serial master to Modbus serial slave communications
2 Ethernet ports with the same IP or dual IP addresses for network redundancy
SD card for configuration backup/duplication and event logs
Accessed by up to 256 Modbus TCP clients
Connects up to Modbus 128 TCP servers
RJ45 serial interface (for “-J” models)
Serial port with 2 kV isolation protection (for “-I” models)
Dual VDC or VAC power inputs with wide power input range
Embedded traffic monitoring/diagnostic information for easy troubleshooting
Status monitoring and fault protection for easy maintenance
-
MGate 5101-PBM-MN Series
1-port PROFIBUS-to-Modbus TCP gateways
Features and Benefits
Protocol conversion between PROFIBUS and Modbus TCP
Supports PROFIBUS DP V1 master
Supports Modbus TCP Client (Master) / Server (Slave)
Automatic scan of PROFIBUS devices and easy configuration
Web-based GUI for I/O data visualization
Embedded traffic monitoring/diagnostic information for easy troubleshooting and cloud data transmission for cost evaluation and analysis
Status monitoring and fault protection for easy maintenance
Supports redundant dual DC power inputs and 1 relay output
-40 to 75°C wide operating temperature models available
Serial port with 2 kV isolation protection